| Sign In | Join Free | My gastesters.com | 
 | 
Brand Name : Taikang
Model Number : Model L125TH L150TH L150TH2 L200TH L225TH L250TH
Certification : CE
Place of Origin : China
MOQ : 1
Price : negotiate
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : negotiate
Delivery Time : 7 days
Packaging Details : wood
noise : 58~64dB(A)
Refrigerant : R410A
power : Three-phase380V/~/50Hz
Model : L125TH L150TH L150TH2 L200TH L225TH L250TH
Humidity setting range and control accuracy : 45~65%±5%
Temperature setting range and control accuracy : 18~25℃±1℃
items : cabinet type (combined) frequency conversion constant temperature and humidity
Type : PTC electric heater
Evaporator : Copper tube finned
number of p : 2 3 5 6 6 8 9 10 P
Factory Air Conditioner is used for indoor air conditioning under various environmental conditions, and has multiple functions. Temperature control range: when the temperature is set at 18-25°C, the control accuracy is ±0.5-1°C, the relative humidity is set at 50-70%.
Factory Air Conditioner Dehumidification principle:
Humidification: Start the humidifier, and the water vapor generated by the humidifier is continuously sent into the room by the fan to achieve the purpose of humidification..
Technical Parameters
| items | frequency conversion constant temperature and humidity | ||||||||
| Model | Indoor Unit | L125TH | L150TH | L150TH2 | L200TH | L225TH | L250TH | ||
| outdoor unit | TK-125WB | TK-150WB | TK-150WB | TK200WB | TK225WB | TK250WB | |||
| indoor unit | air volume | m3 / h | 2500 | 3600 | 3500 | 5000 | 5000 | 5400 | |
| External residual pressure | Pa | 50/0 | 60/0 | 80/0 | 80/0 | 80/0 | 80/0 | ||
| noise | dB(A) | 58/60 | 58/60 | 58/60 | 62/64 | 62/64 | 62/64 | ||
| Temperature setting range and control accuracy | 18~25℃±1℃ | ||||||||
| Humidity setting range and control accuracy | 45~65%±5% | ||||||||
| power | 220V/~/50Hz | Three-phase380V/~/50Hz | |||||||
| Power | kW | 0.16 | 0.18 | 0.16 | 0.22 | 0.24 | 0.26 | ||
| heater | Type | PTC electric heater | |||||||
| Power | kW | 8 | 11 | 11 | 14 | 16 | 18 | ||
| Humidifier | Type | PTC electric heater | |||||||
| Maximum input power | kW | 8.5 | 11 | ||||||
Factory Air Conditioner Application
The unit has a variety of models to choose from, and can be widely used in the air conditioning needs of electronic factories, hospitals, pharmaceutical factories, printing factories, post and telecommunications, banks, computer rooms, power supply and distribution stations, communication stations and other buildings.
Factory Air Conditioner Cooling principle:
When the refrigeration system is working, the high-temperature and high-pressure R410 gas discharged from the compressor enters the condenser and is condensed into a medium-temperature supercooled liquid.


|   | 
| R410A Wine Cellar Air Conditioner Copper Tube Finned Evaporator 45-65%±5% Humidity Images | 
 Relative Humidity 50-70% Wine Cellar Air Conditioners Control Accuracy ±5-10%
                                                                                    
                        
                        
                        
                                                            Relative Humidity 50-70% Wine Cellar Air Conditioners Control Accuracy ±5-10%
                                                    
                        
                     Wine Cellar Cabinet Type Air Conditioner Combined Frequency Conversion
                                                                                    
                        
                        
                        
                                                            Wine Cellar Cabinet Type Air Conditioner Combined Frequency Conversion
                                                    
                        
                     Three Phase 380V R410A Refrigerant Wine Cellar Air Conditioners PTC Electric
                                                                                    
                        
                        
                        
                                                            Three Phase 380V R410A Refrigerant Wine Cellar Air Conditioners PTC Electric
                                                    
                        
                     2 3 5 6 8 9 10P Three Phase Air Conditioner Humidity Setting Range 45-65%±5%
                                                                                    
                        
                        
                        
                                                            2 3 5 6 8 9 10P Three Phase Air Conditioner Humidity Setting Range 45-65%±5%
                                                    
                        
                     External Residual Pressure 50 60 80Pa Wine Cellar Air Conditioners Noise 52-64DB
                                                                                    
                        
                        
                        
                                                            External Residual Pressure 50 60 80Pa Wine Cellar Air Conditioners Noise 52-64DB